[vc_row][vc_column width=”1/4″ el_class=”sidebar copper-side”][vc_row_inner el_class=”widget widget_block”][vc_column_inner][vc_custom_heading text=”Others” use_theme_fonts=”yes”][vc_wp_custommenu nav_menu=”68″][/vc_column_inner][/vc_row_inner][/vc_column][vc_column css_animation=”fadeInDown” width=”3/4″][vc_row_inner][vc_column_inner width=”1/2″][vc_custom_heading text=”Surge Protector” use_theme_fonts=”yes” css=”.vc_custom_1696078624886{margin-top: 30px !important;}”][/vc_column_inner][vc_column_inner width=”1/2″ css=”.vc_custom_1695038988474{padding-top: 30px !important;}”][vc_btn title=”Download Datasheet” color=”primary” align=”right” css=”” link=”url:https%3A%2F%2Fwww.cabcommsystem.com%2Fwp-content%2Fuploads%2F2025%2F05%2FCS-129-1-Surge-Protector.pdf|target:_blank”][/vc_column_inner][/vc_row_inner][vc_single_image image=”2330″ img_size=”full” style=”vc_box_shadow”][vc_column_text]DESCRIPTION:
WTH -SG/RJ45 Series surge protective devices are applied to surge protection for data communication systems and are connected in series in CAT6 network cables, compatible with 10/100/1000/10000 (10G) Base-T Ethernet systems, protecting the equipment which is connected to the network (e.g. computers, routers, PoE devices, etc.) against damages by overvoltage surge. (Standards compliance: IEC61643 -21,
UL497B, IEEE 802.3af PoE/802.3 at PoE Plus)[/vc_column_text][vc_empty_space height=”30px” el_class=”clear clearfix”][vc_column_text css=”.vc_custom_1696080115625{padding-top: 0px !important;}”]SPECIFICATION:
| Model | WTH-SG/RJ45 |
| Ordering code | US121012 |
| Nominal operating voltage (Un) | 2.8V(Ethernet)/48V(PoE) |
| Max. continuous operating voltage (UC) | 3V(Ethernet)/60V(PoE) |
| Nominal Discharge Current (In @8/20μs) | 3kA (line to line) |
| Max. Discharge Current (Imax @8/20μs) | 20kA (line to GND/PE) |
| Voltage protection level (Up @line-line) | 50V @ 3kV (1.2/50) |
| Voltage protection level (Up @line-GND/PE) | 700/800V @ 3kV (1.2/50) |
| Max Line Current | 600mA (PoE) |
| Data Rate | 100/1000Mbps |
| Bandwidth (3db) per pair | >250MHz |
| Insertion Loss | <0.5dB @100MHz |
| Pairs Protected | 1-2,3-6,4-5,7-8 |
| Protective Element | GDT, TVS |
| Voltage Breakdown Range, Vdc @ 100 V/s | 2.4-188 (L-L) / 72-108(L-G) |
| Impulse Voltage Range, DC @ 100 V/μs | <1000 |
| Response Time (tA) | <100ns (line-GND/PE), <1ns (line-line) |
| Connection mode | RJ45 |
| Temperature Range | – 40° to 176°F (-40° to 80°C) |
| Relative Humidity | 0% to 95% noncondensing |
| Maximum Operating Altitude | 10,000 feet (3000m) |
| Cross-sectional area of earth lead | 3mm² multistranded / flexible |
| Stripping Length Contacts | 0.25inches (6-7mm) |
| Terminal Screw Torque | Max. 0.25Nm |
| Protection Rang (IP Code) | IP 20 |
| Surge Life at 0.5kA (8/20μs) | >2000 events |
| DIN Rail EN60715 | 35mm top-hat rail |
| Housing Material | Thermoplasc, UL94 V-0 |
| Net Weight Per Unit | 0.16Lb (71g) |
| Package Dimension (W×D×H) | 0.9″×2.0″×3.1″ (24mm×51mm×78mm) |